Finden Sie schnell aux lightning kabel für Ihr Unternehmen: 272 Ergebnisse

RE-2Y(St)2YSWAY-fl-PIMF

RE-2Y(St)2YSWAY-fl-PIMF

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 2MULTİ-PAİR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation: PE compound, BS 6234 Type03 Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Standard: BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-2G(St)HSWAH-CI-PIMF  FE180

RE-2G(St)HSWAH-CI-PIMF FE180

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / Blue cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 300 MΩ.km Mutual Capacitance: max. 150 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC